SAFE CleanBoxSTK 113

SAFE CleanBox STK 113 high-volume model with automatic tray loaders

The most extensive version in the range for high-volume sterile processing. In addition to the STK 103 workstation, the STK 113 includes automatic tray loaders and a tray set for handling instrument baskets.

98.2%

98.2%

clean instruments

1 s = 40 s

1 s = 40 s

vs. manual brushing

2100 mm

2100 mm

vertical feed and discharge

stk-113 product image without background

Why give up the brush?

Why give up the brush?

Why give up the brush?

Effective

Removes even stubborn dirt in seconds — also from seams and joints that a brush cannot reach.

Secure

Closed handling protects the user from splashes and needlestick injuries. Soda is completely biodegradable.

Economical

The gentle method extends the lifespan of the instruments and frees up working time for other things.

TRADITIONAL CLEANING PROCESS

0,0 %

clean instruments

BICARMED® CLEANING PROCESS

0,0 %

clean instruments

SAFE CleanBox STK 113 in use
SAFE CleanBox operation
SAFE CleanBox detail

Technical specifications in brief

Usage

Central sterile services

Working position

Seated

Frame

Wide 2100 mm workstation

Vertical feeder

Yes

Vertical discharging device

Yes

The most suitable choice

Centralised sterile services department without its own instrument feed line

Compare with other models same method

Compare with other models same method

Compare with other models same method

stk-100 product image without background

STK 100

SafeClean BoxSTK 100

The BICARmed method cleans reusable medical instruments with a mixture of sodium bicarbonate, air and water. An effect equivalent to 40 seconds of manual brushing is produced in about one second of sodium bicarbonate treatment.

stk-103 product image without background

Stock 103

SafeClean BoxStock 103

A wide workstation model designed for centralised sterile services. Features the same closed chamber, internal touch panel, soda and rinse nozzle, and an ergonomic seated workstation without automatic tray loaders.

FAQ

Frequently asked questions about SafeClean Box

Frequently asked questions about SafeClean Box

Frequently asked questions about SafeClean Box

Is your question not on the list? Get in touch — we can also arrange a presentation on your own premises.

Is soda pre-treatment suitable for all instruments?

+

What happens to the cleaning agent after use?

+

Which model is right for us — STK 100, 103 or 113?

+

E-SITE · PDF

Order the brochure to your email

Order the brochure to your email

You will receive the BICARmed® brochure, model comparison, and measurement data directly in your inbox.

Sizing assistance

Not sure about the model?

Not sure about the model?

Tell us about your sterile processing volume and instrument types — we will recommend the suitable size and arrange a demonstration.

Do you want to see the device in action?

Do you want to see the device in action?

Do you want to see the device in action?

Let us arrange a demonstration for your sterilisation department — or ask for a quote directly.